Skip to main content

ACT Machine Cardiac, Cath Lab, ICU: Sonoclot analysis in coronary artery surgery - unstable coronary artery disease treated with enoxaparin

J Cardiothorac Vasc Anesth. 2008 Oct;22(5):670-4. Epub 2008 Mar 24.

Sonoclot analysis in coronary artery surgery: a comparison between patients with unstable coronary artery disease treated with enoxaparin before surgery and patients with stable coronary artery disease not treated with enoxaparin.

Pleym H, Wahba A, Bjella L, Stenseth R.

Department of Cardiothoracic Anesthesia and Intensive Care, St Olav University Hospital, Trondheim, Norway. hilde.pleym@stolav.no

Abstract

OBJECTIVES: To investigate whether perioperative Sonoclot analyses could identify differences in hemostatic function between a group of patients with unstable coronary artery disease treated with low-molecular-weight heparin until the evening before surgery and a group of patients with stable coronary artery disease not treated with lowmolecular-weight heparin.

DESIGN: Prospective and observational investigation.

SETTING: A university hospital, single institution.

PARTICIPANTS: Patients scheduled for coronary artery bypass surgery.

INTERVENTIONS: Blood samples for Sonoclot analysis were drawn preoperatively, 5 minutes after the administration of heparin, immediately after and 20 minutes after cardiopulmonary bypass was established, and 30 minutes and 3 and 20 hours after the end of surgery in a group of patients with unstable coronary artery disease and a group of patients with stable coronary artery disease.

MEASUREMENTS AND MAIN RESULTS: The Sonoclot variables sonACT, coagulation rate, time to peak, amplitude of the peak, and R3 were recorded. The sonACT was significantly lower in the enoxaparin group compared with the control group, whereas the coagulation rate was significantly higher in the enoxaparin group. There were no statistically significant differences in time to peak, amplitude of the peak, and R3 between the 2 study groups.

CONCLUSIONS: The presence of a hypercoagulable state in patients with unstable coronary artery disease is indicated by the significantly higher coagulation rate observed in this group compared with the control group. Further larger studies are needed for evaluation of the usefulness of Sonoclot analysis in the monitoring of hemostatic function in patients with unstable coronary artery disease.

PMID: 18922421 [PubMed - indexed for MEDLINE]


For More Information: www.lifediagnostica.com



Comments

Popular posts from this blog

Life Diagnostica Wishes Happy New Year

  HAPPY NEW YEAR   Life Diagnostica Best ACT Machine Sonoclot CTVS Liver Transplant ICU CCU Thromboelastography TEG 5000 Surgical Headlight Biopsy Containers PreFilled   www.lifediagnostica.com   Life Diagnostica Best ACT Machine Sonoclot CTVS Liver Transplant ICU CCU Thromboelastography TEG 5000 Surgical Headlight Biopsy Containers PreFilled www.lifediagnostica.com

Comparison of Sonoclot with Thromboelastography TEG in Liver Transplant

Comparison of Sonoclot with Thromboelastography TEG in Liver Transplant Sample I: Sonoclot showed that the patient is having Platelet Dysfunction. Total Testing Time for Sonoclot: 18 mins for Thromboelastography TEG: 112 mins and it showed Factor deficiency Sample II: Sonoclot showed that the patient is having Platelet Dysfunction. Total Testing Time for Sonoclot: 18 mins for Thromboelastography TEG: 55 mins and it showed Factor deficiency Sample III: Sonoclot showed that the patient is having Platelet Dysfunction. Total Testing Time for Sonoclot: 18 mins for Thromboelastography TEG: 48 mins and for the first time it showed Platelet Dysfunction Sample IV: Sonoclot showed that the patient is having Platelet Dysfunction. Total Testing Time for Sonoclot: 19 mins for Thromboelastography TEG: 67 mins and it confirmed Sonoclot analysis of Platelet Dysfunction Sample V:  Sonoclot showed that the patient is having Platelet Dysfunction. Total Te...

Life Diagnostica Wishes Happy Holi

  HAPPY HOLI   Life Diagnostica Best ACT Machine Clotz Sonoclot CTVS Liver Transplant ICU CCU Thromboelastography TEG 5000 Surgical Headlight Biopsy Containers PreFilled   www.lifediagnostica.com   Life Diagnostica Best ACT Machine Clotz Sonoclot CTVS Liver Transplant ICU CCU Thromboelastography TEG 5000 Surgical Headlight Biopsy Containers PreFilled